bing tracking image

Filter Questions and Answers:

reset filter

Expert Answers about Cold Air Intakes


  • How Many Stages are There for Airaid Cold Air Intakes
  • Airaid offer cold air intakes in two stages. Stage 1 being a new filter and a box that isolates it from engine air which is warmer and stage 2 which includes that plus a new pipe that connects the air box to the throttle body of the vehicle. The # AR300-236 is stage one. If you let me know what vehicle you have I can let you know what your best option is.
    view full answer...

  • Would the Airaid MXP Cold Air Intake # AR401-278 Cause a Check Engine Light for 2012 Ford F350
  • If the Airaid MXP Cold Air Intake System # AR401-278 were to cause a check engine light to turn on it would have to be installed improperly and it would happen immediately, not 1,200 miles down the road. Without knowing what code your truck popped it would be hard for me to speculate what the real problem is, but as long as you installed the # AR401-278 properly and plugged in all of the sensors it should not cause a vehicle to throw any codes. I would suspect the problem is elsewhere...
    view full answer...

  • Edge Evolution Programmer OBDll Code P2004 and P2006
  • The P2004 manifold runner control stuck open and P2006 manifold runner control stuck closed OBDII code is being read directly from the engines PCM, so it's not being caused by the programmer. It's recommended that you check the intake runner control module actuator or for a restricted vacuum line. This could also be indicative of failure of the PCM itself.
    view full answer...

  • Why is Fogatti Tankless Water Heater Not Heating
  • For your Fogatti RV Tankless Water Heater, # LSB64FR many times when it will not heat is because a safety feature is preventing it from operating. Ensure the air intake and exhaust is clear allowing for full burn of propane. Ensure the propane tank valve is fully opened and that you do not have any blown fuses in the system.
    view full answer...

  • Solution for PO420 and PO430 Code on a 2008 Ford F-150 with 5.4 Liter V8
  • These codes are typical after a header install on your 2008 Ford F-150. The 02 sensors have been relocated farther downstream. The 02 sensors take samples at timed intervials based on exhaust pulses and their location. Now that's thrown out the window. They are still taking samples but the timing is off with the exhaust pulse due to the new location. I have an easy solution for you that has been proven to work to solve the issues you are having. Edge was right when they said the issue...
    view full answer...

  • Furrion RV AC Leaking Water From The Intake
  • There are a couple reasons why your Furrion Chill Replacement RV Air Conditioner for Furrion Setup # FR26PR is leaking water through the intake. This could be caused by the drainage openings being clogged, or the roof gasket is damaged and should be replaced. If the drainage openings are clogged, I suggest attempting to clean them out and seeing if the issue is resolved. If not, you'll need to replace the gasket with # CAM25071.
    view full answer...

  • Is Programmer Difficult to Install on 2007 Toyota FJ Cruiser
  • Programmers are truly plug and play in that all you need to do is plug them in to your OBDII port and the let the programmer guide you through the install process. No mechanic would be needed at all. An Insight like the CS2 part # EP84030 that you referenced is not required either. It could be used with a programmer that didn't come with any monitoring type displays but definitely not needed. That said we do not have any programmers for your 2007 Toyota FJ Cruiser that will give you additional...
    view full answer...

  • Troubleshooting A Furrion RV Air Conditioning Unit Leaking Condensation Into The Vehicle
  • The two possible causes for your Furrion Air Conditioner # FR92PR to be leaking condensation into the vehicle are that your condensation drainage openings on the unit are clogged or the roof gasket is damaged and needs to be replaced. More than likely the drainage openings are clogged and just need to be cleaned out but if they aren't then you can use the Camco Universal Fit RV Roof Air Conditioner Gasket Kit # CAM25071 to replace your current roof gasket.
    view full answer...

  • Trouble Shooting Hot And Cold Water Problems In Tankless Water Heater.
  • Thanks for reaching out, I have a solution for you. In regard to the Fogatti RV Tankless Water Heater - Gas - Automatic Pilot - 41,800 Btu - Black # LSB44FR. First thing I recommend is to check all the exhaust and intake locations to make sure nothing is blocked or damaged. It is not uncommon this time of the year for animals to try and make homes in the the outside compartments of RVs. Next check if it could be a low water pressure issue. If the water pressure gets to low the flow sensor...
    view full answer...

  • Meaning of 88 Error Code on Furrion RV Fireplace
  • The 'BB' is actually an '88', which means that the fireplace blower fan is overheating. This most commonly occurs if the vent air intake atop the unit and the mesh on the front of the fireplace is partially or fully obstructed. Once you've checked the intake/outlet and removed any obstructions, unplug the fireplace for 15-20 minutes to allow the logic board to reset. Furrion says that turning off the unit at the switch isn't always enough to reset the unit. Also, if the unit is running...
    view full answer...

  • Can the Air Filter for a 2008 Ford F-350 Super Duty 6.4 Liter Turbo Collapse into the Turbo
  • The air filter # AR861-348 was designed to work with stock intake system. Regarding the air filter never failing, unfortunately I could not guarantee that but it does have a lifetime warranty. It's highly unlikely an air filter would collapse and get pulled into the turbo. Also, we haven't had any customers report anything of that nature either. I included a link showing all the air filters for your 2008 Ford F-350 Super Duty 6.4 Turbo.
    view full answer...

  • Troubleshooting Furrion RV Fireplace that Stopped Working
  • If the display of your Furrion fireplace is showing 88 then that would indicate it is overheating but if you aren't seeing that and it is just not working at all it most likely has an internal problem and would need to get replaced. Overheating most commonly occurs if the vent air intake atop the unit and the mesh on the front of the fireplace is partially or fully obstructed. Once you've checked the intake/outlet and removed any obstructions, unplug the fireplace for 15-20 minutes to...
    view full answer...

  • Can Fan on Atwood Air Command RV AC 15028 Be Turned Off
  • To prevent the overall temperature of the actual AC Unit to affect the temperature reading, the fan is designed to run all the time. There is a sensor located in the return air intake side of the Atwood Air Command Rooftop RV Air Conditioner # AT15028-22, which blows air from the inside of your RV onto the thermostat. This feature cannot be turned off as this is designed to get the most accurate reading of the interior temperature of your RV. The fan button allows you to switch between...
    view full answer...

  • Advent Air Conditioner Runs But Does Not Blow Cold Air
  • There are a number of reasons why your Advent Air RV Air Conditioner # ACM135 is running but not blowing cold air. The first thing I would check is that the thermostat is set correctly. Ensure that it is set to cool, and that the unit isn't set to just run the fan only. It is unlikely since you mentioned it's a new unit, but I would also check your filter, and make sure that it is clean and not full of debris. Finally, I would attempt a reset. To do this, you will need to start with...
    view full answer...

  • Troubleshooting 13,500 Btu Advent Air RV Air Conditioner Not Blowing Cold Air
  • I reached out to my contact at Advent who said that there are a variety of things that could be causing the issue you are experiencing with the Advent Air RV Air Conditioner # ACM135C. Some of these include problems with the ducts, not taping everything off correctly, or possibly no voltage to the blue wire for powering the compressor. If you are familiar with troubleshooting AC units then you can check these things otherwise it would be best to take your setup in to a service center as...
    view full answer...

  • Troubleshooting Firestone Coil-to-Air-Spring Conversion Kit Deflating in Extreme Cold on 2016 Ram
  • The best thing you can do is make sure you have additional air pressure in your # F2595 when the temperatures are going to be that low. According to Firestone, these air springs are tested to -40 so they are able to handle the cold you're experiencing. If you had them set at the correct psi at a higher temperature you're going to have to add extra air when you know it will reach those sub zero temps. More than likely the shop was heated to above freezing, so you're talking about at least...
    view full answer...

  • Troubleshooting MaxxAir Roof Vent Fan Remote Issues
  • Since you haven't lost any functionality in your fan and you already replaced the batteries the remote itself could be bad. The replacement remote is the Replacement Handheld Remote for Maxxair Roof Vent Intake/Exhaust Fans - Qty 1 # MA00A01150K. You'll also want to ensure there is a clear sightline from your remote to the sensor on the fan.
    view full answer...

  • Advent AC ACM150 Cuts Off
  • Thank you for your purchase from etrailer of the Advent Air RV Air Conditioner # ACM150. What is happening is called short cycling and there are a couple of reasons why that might happen. Most often, the issue is with the thermostat reading the temperature incorrectly, maybe due to air blowing at the thermostat. When the thermostat senses cold air, it will turn on and off quickly - short cycling. If you can re-direct the air to not blow right on or near the thermostat that may resolve the...
    view full answer...

  • Troubleshooting A MaxxAir 5100K Remote That Is Not Operating The Fan
  • Since you've already verified the batteries are good, and that the buttons on your MaxxFan Deluxe Roof Vent w/ 12V Fan and Thermostat # MA00-05100K are working properly, then you may just have a bad remote. To replace your remote, you can use the: -Replacement Handheld Remote for MaxxAir Roof Vent Intake/Exhaust Fans # MA00A01150K. You'll also want to verify that your remote has clear line of sight to the fan and that nothing is blocking the sensor on the fan.
    view full answer...

  • Troubleshooting MaxxAir MaxxFan Roof Vent Beeping When Used for Exhaust
  • Have you tried hooking up your MaxxAir MaxxFan Plus Roof Vent # MA00-04000K since you've disconnected the circuit board? In the past when we've reached out to MaxxAir about that beeping sound they have told us to start off by disconnecting the unit from power, waiting for a few minutes, and then connecting it again to reset the circuit board. Try doing this and let me know if that fixes the issue or not.
    view full answer...